Constant voltage
High efficiency, high reliability
AC input range selectable by switch
Protections: Short circuit / Overload / Over voltage/ Over temperature
Cooling by free air convection
Withstand 300vac surge input for 5 second
Built-in constant current limiting circuit
100% full load burn-in test
LED indicator for power on
Fixed switching frequency at 90KHz
Low cost,high reliability
2 years warranty
Input:
Voltage Range: 90 ~ 132VAC / 180 ~ 264VAC selected by switch
FREQUENCY RANGE: 47 ~ 63Hz
AC Current: 4.5A/115VAC 2.5A/230VAC
Inrush Current: 40A/115VAC 55A/230VAC
Leakage Current: <3.5mA / 240VAC
Output:
|
Model No.
|
DC Voltage & Current
|
Voltage Tolerance
|
RATED POWER
|
RIPPLE & NOISE (max.)
|
Efficiency
|
|
NES-200-3.3
|
3.3V / 40A
|
2%
|
132W
|
80mVp-p
|
73%
|
|
NES-200-5
|
5V /40A
|
2%
|
200W
|
80mVp-p
|
78%
|
|
NES-200-7.5
|
7.5V / 27A
|
2%
|
202.5W
|
120mVp-p
|
80%
|
|
NES-200-12
|
12V /17A
|
1%
|
204W
|
120mVp-p
|
83%
|
|
NES-200-15
|
15V / 14A
|
1%
|
210W
|
120mVp-p
|
83%
|
|
NES-200-24
|
24V / 8.8A
|
1%
|
211.2W
|
120mVp-p
|
83%
|
|
NES-200-27
|
27V / 7.8A
|
1%
|
210.6W
|
200-p
|
86%
|
|
NES-200-36
|
36V / 5.9A
|
1%
|
212.4W
|
24Vp-p
|
86%
|
|
NES-200-48
|
48V / 4.4A
|
1%
|
211.2W
|
24 p-p
|
86%
|
Protection:
1. Overload Protection: 105 ~ 150% rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is removed
Environment:
Working Temp / Humidity: -20℃~+5℃ / 20%~90 %RH
Storage Temp / Humidity: -40℃~+85℃ / 10%~95 %RH
Vibration: 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
Safety & EMC:
Safety Standard: UL60950-1 approved
Withstand Voltage: I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
Isolation Resistance: I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃ / 70% RH
EMI CONDUCTION & RADIATION: Design refer to EN55022 (CISPR22) Class A
Dimension &Weight & Packing: 215*115*50mm (L*W*H); 0.93Kg; 12pcs/12Kg/0.92CUFT
------------------------
Notice:
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
|
|
|
|
|