Features:
Constant voltage
High efficiency, high reliability
AC input range selectable by switch
100% full load burn-in test
2 years warranty
MTBF:271.9K hrs min. MIL-HDBK-217F (25℃)
Input:
Voltage Range: 90~132 VAC /176~264VAC selectable by switch
FREQUENCY RANGE: 47 ~ 63Hz
AC Current: 4.8A/115VAC, 2.8A/230VAC
Inrush Current: Cold start, 45A at 230VAC
Leakage Current < 2mA/240VAC
Output:
Model No. | DC Voltage & Current | Voltage Tolerance | RATED POWER | RIPPLE & NOISE (max.) | Efficiency |
S-150-5 | 5.0V / 30A | 2% | 150W | 150mVp-p | 78% |
S-150-7.5 | 7.5V / 20A | 1% | 150W | 150mVp-p | 80% |
S-150-9 | 9V / 16.7A | 1% | 150.3W | 180mVp-p | 80% |
S-150-12 | 12V / 12.5A | 1% | 150W | 180mVp-p | 82% |
S-150-13.5 | 13.5V / 11.2A | 1% | 151.2W | 180mVp-p | 83% |
S-150-15 | 15V / 10A | 1% | 150W | 180mVp-p | 84% |
S-150-24 | 24V / 6.5A | 1% | 156W | 240mVp-p | 85% |
S-150-27 | 27V / 5.6A | 1% | 151.2W | 240mVp-p | 86% |
S-150-48 | 48V / 3.2A | 1% | 153.6W | 240mVp-p | 87% |
Protection:
1. Overload Protection: 105 ~ 150% rated output power,
Protection type: Hiccup mode, auto-recover after fault condition is removed
2. Over Voltage Protection: 105%~135% rated output voltage
Protection type: Hiccup mode, auto-recover after fault condition is removed
Environment:
Working Temp / Humidity: -10℃~+60℃ / 20%~90 %RH
Storage Temp / Humidity: -20℃~+85℃ / 10%~95 %RH
Vibration: 10~500Hz,2G 10min./1cycle,period for 60min, each along X, Y, Z axes
Safety & EMC:
Safety Standard: UL1012, UL60950-1, TUV EN60950-1 Approved
Withstand Voltage: I/P-O/P: 3KVAC, I/P-FG: 1.5KVAC, O/P-FG: 0.5KVAC
Isolation Resistance: I/P-O/P, I/P-FG, O/P-FG: 100M Ohms/500VDC
EMI CONDUCTION & RADIATION: Compliance to EN55022 (CISPR22) Class B
HARMONIC CURRENT: Compliance to EN61000-3-2,-3
EMS IMMUNITY: Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, Light industry level, criteria A
Dimension &Weight & Packing: 199*110*50mm (L*W*H); 0.8kg/pc; 16pcs/13.8Kg/0.95CUFT
--------------------------------------------------------------------------------------------------------------------------------
Notice:
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance: includes set up tolerance, line regulation and load regulation.