Constant voltage
High efficiency, high reliability
Universal AC input/Full range
Protections:Short circuit/Over load/Over voltage
Cooling by free air convection
100% full load burn-in test
2 years warranty
Input:
Voltage Range: 85 ~ 264VAC
FREQUENCY RANGE: 47 ~ 63Hz
AC Current: 1.1A/115VAC 0.65A/230VAC
Inrush Current: COLD START 45A
Leakage Current: <2mA / 240VAC
Output:
|
Model No.
|
DC Voltage & Current
|
Voltage Tolerance
|
RATED POWER
|
RIPPLE & NOISE (max.)
|
Efficiency
|
|
NES-50-5
|
5.0V / 10A
|
2%
|
50W
|
80mVp-p
|
79%
|
|
NES-50-12
|
12V /4.2A
|
1%
|
50.4W
|
120mVp-p
|
82%
|
|
NES-50-15
|
15V / 3.4A
|
1%
|
51W
|
150mVp-p
|
83%
|
|
NES-50-24
|
24V /2.2A
|
1%
|
52.8W
|
200mVp-p
|
86%
|
|
NES-50-48
|
48V / 1.1A
|
1%
|
52.8W
|
240mVp-p
|
87%
|
Protection:
1. Overload Protection: 110 ~ 150% rated output power
Protection type : Shut down o/p voltage, re-power on to recover
Environment:
Working Temp / Humidity: -20℃~+60℃/ 20%~90 %RH
Storage Temp / Humidity: -40℃~+85℃/ 10%~95 %RH
Vibration: 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
Safety & EMC:
Safety Standard: UL60950-1, CB(IEC60950-1),GB4943 approved
Withstand Voltage: I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
Isolation Resistance: I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
EMI CONDUCTION & RADIATION: Compliance to EN55022 (CISPR22) Class B,GB9254 CLASS B
Dimension &Weight & Packing: 129*98*38mm (L*W*H); 0.41Kg; 30pcs/13.3Kg/0.72CUFT
------------------------
Notice:
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Line regulation is measured from low line to high line at rated load.
5. Load regulation is measured from 0% to 100% rated load.
6. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets . EMC directives. For guidance on how to perform these EMC tests, please refer to .EMI testing of component power supplies.
|