Features:
Constant voltage
High efficiency, high reliability, Low cost
AC input range selectable by switch
100% full load burn-in test
Fixed switching frequency at 25KHz
MTBF:322.4K hrs min. MIL-HDBK-217F (25 )
1 years warranty
Input:
Voltage Range: 85~132 VAC /180~264VAC selectable by switch
Frequency Range: 47 ~ 63Hz
AC Current: 2.4A/115VAC, 1.2A/230VAC
Inrush Current: Cold start, 30A at 115VAC, 60A/230VAC
Leakage Current < 1mA / 240VAC
Output:
Model No. | DC Voltage & Current | Voltage Tolerance | RATED POWER | RIPPLE & NOISE (max.) | Efficiency |
s-100-3 | 3V / 20A | 2% | 60W | 100mVp-p | 70% |
s-100-5 | 5V / 20A | 2% | 100W | 100mVp-p | 78% |
s-100-7.5 | 7.5V / 13.6A | 1% | 102W | 100mVp-p | 80% |
s-100-10 | 10V / 10A | 1% | 100W | 100mVp-p | 80% |
s-100-12 | 12V / 8.5A | 2% | 102W | 100mVp-p | 81% |
s-100-15 | 15V / 6.7A | 1% | 100.5W | 100mVp-p | 81% |
s-100-18 | 18V / 5.6A | 1% | 100.8W | 100mVp-p | 82% |
s-100-24 | 24V / 4.5A | 1% | 108W | 100mVp-p | 84% |
s-100-27 | 27V / 3.7A | 1% | 99.9W | 100mVp-p | 84% |
s-100-48 | 48V / 2A | 1% | 96W | 100mVp-p | 84% |
Protection:
Protections: Short circuit, Overload, Overvoltage, Cooling by free air convection
1. Overload Protection: 105 ~ 150% rated output power,
(150 ~ 200% rated output power for S-100-7.5 only)
Protection type: Shut down o/p voltage, re-power on to recover
2. Over Voltage 115%~135%
Protection type: hiccup mode, recovers automatically after fault condition is removed.
Environment:
Working Temp / Humidity: -10℃~+60℃ / 20%~90 %RH
Storage Temp / Humidity: -20℃~+85℃ / 10%~95 %RH
Vibration: 10~500Hz,2G 10min./1cycle,period for 60min, each along X, Y, Z axes
Safety & EMC:
Safety Standard: Design refer to UL1012
Withstand Voltage: I/P-O/P: 1.5KVAC, I/P-FG: 1.5KVAC, O/P-FG: 0.5KVAC
Isolation Resistance: I/P-O/P, I/P-FG, O/P-FG: 100M Ohms/500VDC
EMI CONDUCTION & RADIATION: Design refer to FCC Part15 J Conduction Class B
Dimension &Weight & Packing:
159*97*38mm (L*W*H); 0.51kg/pc; 4pcs/13.1Kg/0.7CUFT
Notice:
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance: includes set up tolerance, line regulation and load regulation.