Feature:
Universal AC input / Full range
Protections: Short circuit / Overload / Over voltage / Over temperature
Built-in active PFC function
IP67 design for indoor or outdoor installations
UL1310 Class 2 power unit
Cooling by free air convection
100% full load burn-in test
High reliability
Suitable for LED lighting and moving sign applications
Compliance to worldwide safety regulations for lighting
Damp / wet location outdoor application
3 years warranty
60W series models:
|
Model No.
|
DC Output
|
R&N
|
Effi.
|
|
CLG-60-12
|
12V, 5A
|
2Vp-p
|
81.5%
|
|
CLG-60-15
|
15V, 4A
|
2.4Vp-p
|
84.5%
|
|
CLG-60-20
|
20V, 3A
|
1.8Vp-p
|
86%
|
|
CLG-60-24
|
24V, 2.5A
|
2.7Vp-p
|
86%
|
|
CLG-60-27
|
27V,2.3A
|
2.7Vp-p
|
86.5%
|
|
CLG-60-36
|
36V, 1.7A
|
3.6Vp-p
|
87%
|
|
CLG-60-48
|
48V,1.3A
|
4.6Vp-p
|
87%
|
AC input voltage range: 90 ~ 264VAC
AC inrush current (max.): 40A/230VAC
OVER CURRENT PROTECTION: 95 ~ 110% Constant current limiting, recovers automatically after
fault condition is removed
Over voltage protection: Shut down o/p voltage, recovers automatically after temperature goes down
Withstand voltage: I/P-O/P:3.75KVAC I/P-FG:1.88KVAC O/P-FG:0.5KVAC
Environment:
Operating Temperature: -30 ~ +70℃(Refer to output load derating curve)
Working Humidity: 20 ~ 95% RH non-condensing
Storage Temp., Humidity: -40℃~ +80℃, 10 ~ 95% RH
Vibration: 10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
Safety Standards:
UL1310 Class 2, TUV EN61347-1, EN61347-2-13, CAN/CSA C22.2 No. 223-M91(except for 48V), IP67 approved
EMC standards:
Compliance to EN55015, EN55022 (CISPR22) Class B
Compliance to EN61000-3-2 Class C (≧75% load) ; EN61000-3-3
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, EN61547, light industry level (surge 4KV), criteria A
1000-3-2 Class C (≧75% load) ; EN61000-3-3
Packing:
0.86Kg; 16pcs/14.8Kg/0.54CUFT